Assembly

Magnetic Lifter

Magnetic lifters are switchable permanent-magnet assemblies for handling steel plate and sections. YUECI KEJI supplies permanent-magnet lifters with manual release, rated per inquiry.

NdFeB + steel body Lifter Switchable Manual release Zinc or epoxy coated
Magnetic Lifter - YUECI KEJI

Applications

Steel plate and sheet handling

Bar, section and pipe handling

Machine loading and press work

Why buyers choose it

  • Switchable: the load is held and released without power, by a manual lever.
  • Permanent-magnet design holds without current, so there is no coil to fail.
  • Rated per inquiry against plate thickness, surface condition and load.
  • Body coated for workshop and outdoor handling duty.

Specifications

MagnetAvailable grades, temperature ratings and coatings are confirmed against your drawing and operating conditions at quotation.
HousingSteel body, zinc-plated or epoxy coated
ShapeSwitchable lifter assembly
CoatingZinc plating / epoxy on request
ToleranceDimensional tolerances are confirmed against the approved drawing and depend on part size, geometry and finishing process. Please identify critical dimensions when requesting a quotation.
MagnetizationSwitchable through the working face
ApplicationsSteel plate handling, Section and bar handling, Machine loading
Lead timeProduction lead time and shipping transit time are quoted separately. The confirmed schedule depends on the approved drawing, quantity, documentation requirements, destination and shipping method.
MOQQuoted per inquiry
Export controlExport classification is confirmed per shipment against the product composition and destination.

What is a magnetic lifter

A magnetic lifter is a switchable permanent-magnet assembly for handling ferrous loads. The magnet is held in a steel body with a manual lever that moves it relative to the circuit: one position puts full flux on the working face and holds the load, the other takes the flux off and releases it.

At YUECI KEJI lifters are supplied as permanent-magnet assemblies with manual release, rated per inquiry against the plate thickness, surface condition and load the job actually presents.

How the gaussmeter works

The lever moves the magnet between an aligned position, where the steel circuit puts full flux on the working face, and an offset position, where the flux is short-circuited inside the body and the face goes dead. Because the magnet is permanent, the load is held with no current and no coil to fail.

The safety case rests on the rating, not the principle: rated load depends on plate thickness, surface condition, alloy and lever setting, which is why the number is quoted per assembly and per duty.

Magnet, material and finish

The magnets are sintered NdFeB in the commercial grade range, carried in a steel body that forms the switching circuit. Bodies are zinc-plated or epoxy coated for workshop and outdoor handling duty.

The permanent-magnet design means there is nothing to power and nothing to overheat, which is why lifters remain standard in press and machine-loading work.

Typical applications

Lifters end up wherever steel has to be picked up and put down repeatedly: plate and sheet handling, bar, section and pipe handling, and machine loading and press work.

Handling, storage and shipping

Lifters ship in padded packing with the working face and the lever protected. The assembly is heavy by design, so cartons are specified for the weight, and the face is kept clean in service to hold its rating.

Custom sizing, prototyping and order minimums

Every assembly is built to your drawing or reproduced from your sample: magnet grade, cup dimensions, thread or fastener, finish and packing. Samples come first, then volume; repeat orders are faster because the tooling and the pull-force routine already exist.

Grade, temperature and coating — how this part is specified

A complete assembly specification names the magnet grade, the cup or housing material and dimensions, the fastener or thread, the finish, the required pull force and the destination. Pull force is quoted against a defined test block, because the number depends on the steel as much as on the magnet.

Designing the magnetic circuit and working on the line

A lifter is specified by the rated load, the plate thickness range and the duty cycle. If the load is missed, the next body size up recovers more than a grade change because the contact area and the circuit both grow with the body.

When to choose a different shape

A lifter is the default for plate handling. Move to a pot or clamp assembly for lighter holding, to a retrieval assembly when the target is debris rather than plate, and to a crane magnet when the load is bulk scrap.

Where this material is typically used

Lifters end up in every shop that moves steel — fabrication, machine loading, press work and stock handling.

Buyer Questions

Magnetic Lifter FAQs

How is the load released?

By a manual lever that moves the magnet relative to the steel circuit, taking the flux off the working face. No power is needed to hold or to release.

What determines the safe working load?

Plate thickness, surface condition, alloy and the lever setting. YUECI KEJI quotes the rated load per assembly and per duty rather than publishing a generic figure.

Are magnetic lifters export Export documentation and licensing requirements are confirmed per shipment.?

Export classification is confirmed per shipment against the product composition and destination.

Request a quote for Magnetic Lifter