Assembly

Magnetic Separator Grid

Magnetic separator grids are tube assemblies of alternating permanent magnets for extracting ferrous contamination from flowing material. YUECI KEJI supplies separator grids to your grid pitch and magnet grade.

NdFeB or ferrite Grid / tube Axial tubes Custom pitch Stainless tubes
Magnetic Separator Grid - YUECI KEJI

Applications

Food, grain and feed flow lines

Pneumatic conveying and dust collection

Chemical and plastic feed systems

Why buyers choose it

  • Tubes of alternating polarity concentrate flux at the surface where material passes.
  • NdFeB for maximum pull, ferrite for high temperature and cost-first duty.
  • Grid pitch and tube spacing specified to the flow rate and the particle size.
  • Stainless tubes and painted frames for food and chemical lines.

Specifications

MagnetAvailable grades, temperature ratings and coatings are confirmed against your drawing and operating conditions at quotation.
HousingStainless steel tubes in a grid frame
ShapeSeparator grid / tube assembly
CoatingStainless tubes; frames painted or plated
ToleranceDimensional tolerances are confirmed against the approved drawing and depend on part size, geometry and finishing process. Please identify critical dimensions when requesting a quotation.
MagnetizationAxial along each tube
ApplicationsFood and grain flow lines, Pneumatic conveying, Chemical and plastic feed
Lead timeProduction lead time and shipping transit time are quoted separately. The confirmed schedule depends on the approved drawing, quantity, documentation requirements, destination and shipping method.
MOQQuoted per inquiry
Export controlExport classification is confirmed per shipment against the product composition and destination.

What is a magnetic separator grid

A magnetic separator grid is an assembly of magnet tubes held in a frame, installed so that flowing material passes across the tube surfaces. Ferrous particles are captured on the tubes and wiped off at cleaning time; the product continues down the line.

At YUECI KEJI grids are supplied to your pitch, tube diameter and magnet grade, in stainless tubes with painted or plated frames, sized to the flow rate and the particle size the line has to catch.

How the gaussmeter works

Each tube carries a stack of magnets of alternating polarity, which concentrates flux at the tube surface in a series of strong points along its length. Material flowing past the tubes passes through those fields, and ferrous particles are held while the product passes.

The design variables are pitch, tube diameter and magnet grade. Pitch sets how much material can flow and how close it passes to a tube; grade sets how strongly the particles are held. Getting the three right against the flow rate is the whole engineering job.

Magnet, material and finish

Tubes carry sintered NdFeB for maximum pull at ambient temperature, or hard ferrite where the line runs hot or the application is cost-first. Tubes are stainless steel; frames are painted or plated to the line environment.

Because the magnets are sealed inside stainless tubes, the assembly survives washdown, food and chemical duty that would destroy exposed magnets.

Typical applications

Separator grids end up wherever ferrous contamination has to come out of a flowing product: food, grain and feed lines, pneumatic conveying and dust collection, and chemical and plastic feed systems.

Handling, storage and shipping

Grids ship with the tubes taped or cushioned in the frame and the faces protected. Stainless tubes are robust in service; the cleaning routine is what keeps the capture rate up.

Custom sizing, prototyping and order minimums

Every assembly is built to your drawing or reproduced from your sample: magnet grade, cup dimensions, thread or fastener, finish and packing. Samples come first, then volume; repeat orders are faster because the tooling and the pull-force routine already exist.

Grade, temperature and coating — how this part is specified

A complete assembly specification names the magnet grade, the cup or housing material and dimensions, the fastener or thread, the finish, the required pull force and the destination. Pull force is quoted against a defined test block, because the number depends on the steel as much as on the magnet.

Designing the magnetic circuit and working on the line

A grid is specified by the flow rate, the particle size to catch and the environment. If capture is short, the cheapest fix is usually a tighter pitch or more tubes rather than a grade change, because contact frequency matters more than field strength once the field is adequate.

When to choose a different shape

A grid is the default for gravity and pneumatic flow. Move to a plate or grate magnet for chute duty, to a liquid-line trap for pumped fluids, and to a drum separator for high-volume free-fall material.

Where this material is typically used

Separator grids end up in every plant that moves bulk material and cannot afford ferrous contamination downstream.

Buyer Questions

Magnetic Separator Grid FAQs

NdFeB or ferrite tubes?

NdFeB for maximum pull at ambient temperature; ferrite where the line runs hot or the application is cost-first. Both are supplied to the same grid geometry.

How is the grid cleaned?

Tubes are drawn from the frame and wiped, or the frame is removed as a unit; the grid is designed for routine cleaning without tools where the line requires it.

Are separator grids export Export documentation and licensing requirements are confirmed per shipment.?

Export classification is confirmed per shipment against the product composition and destination.

Request a quote for Magnetic Separator Grid