Guides

How to Test and Measure a Magnet: Field, Flux and Pull Force | YUECI KEJI

There is a large gap between the number on a datasheet and the field a buyer can measure in the workshop. Knowing what each instrument measures explains the gap.

There is a large gap between the number on a datasheet and the field a buyer can measure in the workshop. Knowing what each instrument measures explains the gap.

Surface field with a Hall probe

A gaussmeter with a Hall probe reads the field at a point near the surface. It is quick and useful for comparison, but it is sensitive to probe position, probe thickness and the local geometry, so readings vary between operators. Treat it as a comparative check rather than an absolute value.

Total flux with a fluxmeter or Helmholtz coil

A fluxmeter measures the total flux leaving the magnet, which is a much better proxy for the magnetic moment than a surface reading. Helmholtz coil measurements are the standard way to characterise a production lot because they average over the whole part.

Hysteresisgraph measurement

A hysteresisgraph traces the full B-H loop and reports remanence, coercivity and energy product directly. This is how a lot is verified against its grade, and it is the measurement to ask for when the specification matters.

Pull-force testing

Pull force is measured against a defined steel plate with a defined geometry, and it depends on the plate, the gap and the surface finish as much as on the magnet. It is the most application-relevant number and the least transferable between setups.

What to ask a supplier for

For production verification, ask for the measured magnetic values per lot against the grade and class, and for the inspection record that travels with the shipment. For your own incoming check, a fluxmeter comparison against a retained reference magnet is the most practical method.

Frequently asked questions

Why does my gaussmeter reading differ from the datasheet? Probe position, probe thickness and local geometry all shift a surface reading. Datasheet figures are material values, not surface field at an arbitrary point.

Which measurement matters for production? Total flux or hysteresisgraph measurement per lot, because those verify the grade rather than a single point.

Is pull force a reliable comparison? Only against a defined plate, gap and setup. Change any of the three and the number changes.

Can you report measured values with my order? Yes. Lot records carry the measured magnetic values against the specified grade and class.

If your question is not covered here, Request a quote and our engineering team will answer it directly. See also testing and measurement.