Neodymium magnets are deceptively tricky to ship by air. They are not hazardous goods in the chemical sense, but their field can interfere with aircraft systems, so regulators treat them with care. This guide to shipping neodymium magnets by air covers what carriers actually check.
The short answer: contain the field, then document it
Air carriers apply IATA rules that limit the magnetic field a package may project. If the field at the package surface and at a defined distance (commonly two metres) stays under the threshold, the shipment travels as normal cargo. If not, it must be shielded, short-circuited or, in extreme cases, moved by another mode. The work is in getting the field down before the box is closed.
Why air freight has magnetic limits
A strong, unconstrained field can affect compasses, navigation and sensitive electronics on board. The rules exist to keep the field around the package low enough that it cannot reach aircraft systems. This is about the package's external field, not the magnet's internal strength.
- Surface limit: a maximum field measured at the outer surface of the package.
- Distance limit: a much lower maximum measured at a set distance, often two metres.
- Pass or fail: both must be met for unrestricted air carriage.
Two ways to bring the field down
Steel shielding
Surrounding the magnets with a steel enclosure diverts the field into the steel and reduces what leaks out. This is effective but adds weight and bulk.
Magnetic short-circuit plates (keeper plates)
Placing a soft-iron plate across the poles of a magnet gives the field a low-resistance path, so it stays mostly inside the plate-magnet-plate loop instead of radiating outward. Paired magnets are often packed pole-to-pole with a keeper between them.
- Principle: the field follows the easy iron path, not the air.
- Benefit: lighter than full shielding, often enough to pass the limit.
- Check: always measure after packing, because arrangements vary.
Measuring before you ship
The field limit is verified with a gauss meter, not assumed. Measure the field at the package surface and at the required distance. If either exceeds the limit, re-pack with more shielding or better short-circuiting and measure again.
- Use a calibrated gauss meter or Hall probe.
- Record the readings as part of the shipment file.
- Re-test if the pack configuration changes.
Packaging and labelling
Even when the field is within limits, carriers expect clear handling. Typical requirements include:
- Magnetic label: where applicable, a 'Magnetized Material' handling mark on the package.
- Secure packing: magnets fixed so they cannot shift and re-orient during transit.
- Documentation: accurate descriptions and, where needed, a statement that the field limits are met.
Working with the carrier and freight forwarder
Air rules are interpreted by the carrier's dangerous-goods or shipping desk. Early communication avoids a rejected shipment at the dock. Share the measured field data and the packing method so they can classify the consignment correctly.
For export shipments of magnetic products, our logistics team coordinates packing, field measurement and documentation so the consignment meets carrier requirements before it leaves the warehouse.
When air is not the right mode
If a very strong assembly cannot be brought within limits economically, sea freight or ground transport may be simpler. The choice is a function of field, volume and urgency, not a fixed rule.
Common mistakes that get shipments rejected
- Assuming a low grade means a low field at the package surface (geometry and count matter).
- Packing without short-circuit plates and discovering the excess at the counter.
- Failing to re-measure after changing the box or stack arrangement.
- Missing or incorrect handling marks on the outer package.
A practical pre-ship checklist
- Define the pack: shielding, keeper plates, orientation.
- Fix magnets so they cannot move.
- Measure surface and distance field with a gauss meter.
- Adjust packing until both limits are met.
- Apply the correct labels and documentation.
- Confirm classification with the carrier before booking.
How a carrier classifies the shipment
When you hand a magnetic parcel to a freight desk, they assess the measured field and decide the classification. If both the surface and distance limits are met, it moves as ordinary cargo with the appropriate handling marks. If the field exceeds the limit, they will require re-packaging, a different mode, or in rare cases refusal. The measurement data you bring removes the guesswork and prevents a rejected shipment at the dock.
Different carriers apply the same underlying rules with their own paperwork, so confirm the exact measurement points and labels with the specific airline or forwarder rather than assuming one size fits all.
Cost and mode trade-offs
Air freight rewards small, light, packages within the field limits; a heavy steel-shielded crate can erase the speed advantage through handling and cost. When the magnet assembly is large or the field is hard to contain, sea or ground transport is often cheaper and simpler, with the only penalty being transit time. The right mode follows from field strength, package mass and how urgent the delivery is, not from a fixed rule that air is always best.
Insurance and liability
Because a mis-declared magnetic shipment can disrupt an aircraft's instruments, carriers treat an undeclared magnetic shipment seriously, and the cost lands on the shipper. Proper field measurement, correct packing and accurate documentation are not paperwork for its own sake; they are what keep the shipment moving and the liability where it belongs. Build the measurement into the packing process rather than treating it as a last-minute check at the counter.
A simple mode decision
If the field is within limits and the part is light, air is usually best. If containing the field needs heavy steel shielding that erases the weight advantage, or if the consignment is large and non-urgent, sea or ground is often cheaper and simpler. The decision follows from field, mass and urgency, so state those three early and the mode selects itself.
Planning the shipment early
The field limit is easiest to meet when it is designed in, not discovered at the dock. Tell the magnet supplier the shipment will fly, ask about pole-pairing and keeper plates, and keep the measured field data with the order. A few minutes of planning in the quotation stage prevents a rejected pallet and a missed delivery window later, which is exactly when air freight matters most.
Frequently asked questions
The shipping questions buyers and logistics teams ask most.
Are neodymium magnets allowed on aircraft? Yes, when the package's external magnetic field is within the IATA limits measured at the surface and at the prescribed distance; otherwise it must be shielded, short-circuited or sent by another mode.
What is a magnetic short-circuit plate? A soft-iron plate placed across the magnet's poles that gives the field an easy path, keeping most of it inside the plate-magnet loop and reducing the field that leaks from the package.
How do I prove the shipment meets the limits? By measuring the field at the package surface and at the required distance with a gauss meter and recording the readings as part of the shipping documentation.
Do I need a special label? Where applicable, a magnetic-material handling mark is applied to the package, along with secure packing and accurate documentation for the carrier.
What if the field cannot be reduced enough? Then sea or ground transport may be the practical option, or the packing must be redesigned with more shielding or better short-circuiting.
Planning an air shipment of magnets? Request a quote and our logistics team will help you pack, measure and document the consignment against the limits.