A magnet's demagnetization curve, usually called the B-H curve, plots the magnetic flux density the material can deliver against the magnetic field applied against it. It is drawn in the second quadrant, because the applied field opposes the magnet's own magnetization, and almost every property quoted in a magnet specification can be read off this one graph.
The axes and the second quadrant
The horizontal axis is H, the applied magnetic field, plotted negative because it works against the magnet. The vertical axis is B, the flux density the magnet delivers at that applied field. Start at the origin: no applied field, and the material delivers its remanence, written Br. Push a field against it, and the delivered flux density falls. The curve traces how far it falls.
The three key readings
- Remanence (Br): the flux density at zero applied field. It is the maximum the material could deliver if nothing pushed back, and it is the number in a grade designation such as N42.
- Coercivity (Hcb): the applied field needed to bring the delivered flux density back to zero. Beyond this point the magnet still holds some magnetization, but it delivers nothing usable.
- Intrinsic coercivity (Hcj): the applied field needed to erase the magnetization itself. This is always a larger number than Hcb, and it is the one that decides temperature class and resistance to demagnetization.
The knee, and why motors care about it
Follow the curve from Br downwards. For a while it falls almost in a straight line, and then it bends sharply, dropping almost vertically. That bend is the knee. Above the knee, the magnet loses flux density but recovers it when the opposing field is removed, a reversible loss. Below the knee, the loss becomes permanent. A motor under overload, or a generator under a short circuit, can push the magnet's working point below the knee, and the magnet is then weaker for the rest of its life even though nothing visible happened.
The working point and the load line
A magnet never operates at Br. It operates at the point where its own curve intersects the load line imposed by the surrounding magnetic circuit, and that point is called the working point. A short, fat magnet in free space sits low on the curve, delivering only a fraction of its remanence. The same material in a long, thin shape, or closed into a steel circuit, sits much higher. This is why geometry is a magnetic specification and not just a mechanical one.
Maximum energy product
The curve also carries the (BH)max figure quoted in MGOe. It is the largest rectangle that fits under the curve, and it represents the most energy the magnet can deliver per unit volume into a matched load. Grades are numbered roughly by it: N42 sits near 42 MGOe, N52 near 52 MGOe. Two magnets with the same (BH)max can still behave very differently if one has a much higher Hcj, which is exactly the difference between a plain grade and one with an H or SH suffix.
Reading the curve for temperature
Ask the supplier for the curve at the temperature your application actually runs at, not only at room temperature. A grade that looks generous at 20 degrees can sit well below the knee at 150 degrees once the reversible temperature losses are applied, and the two temperature coefficients, one for remanence and one for coercivity, act on different parts of the picture. The temperature coefficient article works through the arithmetic.
Frequently asked questions
Why is the curve only drawn in the second quadrant? Because that is the region a permanent magnet operates in. The first quadrant is where the material is being magnetized, and the third and fourth describe opposing fields strong enough to reverse the magnetization.
What does a higher knee mean in practice? It means the magnet tolerates a stronger opposing field before the damage becomes permanent, which is what a motor or generator designer is really buying when they specify an H or SH class.
Can I get the curve for a specific grade? Yes, request the room-temperature curve and the curve at your operating temperature. The grade chart lists the standard values, and we can supply the curves with a quotation.
Does the curve change after the magnet is made? Only if the magnet is damaged by heat or a strong opposing field. A correctly operated magnet's curve is a fixed property of the material and geometry.
Need the curve for a specific grade and temperature? Request a quote and we will attach it to the quotation.