Magnetising direction is one of the most misunderstood specs on a magnet drawing, and getting it wrong means the part physically cannot do its job. The axial vs radial magnetization choice is about where the north and south poles end up, and that determines everything from motor torque to sensor readout.
The short answer: it is about pole location
Axial magnetization puts the poles on the two flat faces of a disc or ring, so the field travels along the axis. Radial magnetization puts the poles on opposite sides of the outer (or inner) curved wall, so the field crosses the diameter. Diametric magnetization is the common two-pole version of radial, with a single north-south pair across the diameter. The right choice follows directly from what the magnet must do in the assembly.
What magnetization direction actually means
A permanent magnet is magnetized along one direction during manufacture, when it is placed in a strong field before or after sintering. That direction fixes where the poles appear and therefore the geometry of the external field.
- Axial: poles on the top and bottom faces; field along the central axis.
- Radial / diametric: poles on opposing curved surfaces; field across the diameter.
At YUECI KEJI our NdFeB magnets are supplied with axial, diametric or radial orientation as the design requires, and the direction is called out on every drawing.
Axial magnetization in practice
This is the simplest and most common configuration. A disc magnet with axial magnetization has north on one face and south on the other. Stack several and their fields add along the axis.
- Typical uses: holding magnets, speaker motors, magnetic couplings where axial pull is wanted.
- Easy to visualise: the field lines leave one flat face and return to the other.
- Multi-pole axial: with segmented or sequenced magnetization, a ring can carry several poles around its face for precise rotor or encoder patterns.
Radial and diametric magnetization in practice
A ring magnetized radially has north on part of its outer wall and south on the opposite side, so the field points outward across the diameter. A diametrically magnetized rod or ring has a single north-south axis across its width.
- Typical uses: rotary encoders, magnetic sensors that read shaft angle, and brushless motor rotors where the field must face the stator across the air gap.
- Key advantage: the field is available at the curved surface, which is exactly where a sensor or stator sits.
For slender parts such as bar and rod magnets, a diametric direction turns a simple cylinder into a clean two-pole switch element for position sensing.
Why the choice changes the function
Consider a ring in a rotary encoder. Axially magnetized, its field points up and down and a sensor above it sees little variation as the ring turns. Radially (or diametrically) magnetized, the field sweeps past the sensor as the ring rotates, producing the sine or square wave the encoder needs. Same material, opposite behaviour, purely because of magnetization direction.
Multi-pole and segmented patterns
Beyond simple two-pole parts, rings can be magnetized with many poles around the circumference (multi-pole radial) for fine angular resolution, or built from arc segments assembled into a rotor. These patterns are defined at magnetization time and must be specified exactly.
How to mark magnetization on a drawing
Ambiguity here is the most common cause of rejected magnets. Use one clear convention:
- Arrows: draw an arrow showing the magnetization axis, with N and S labels at the poles.
- Text callout: state 'Axially magnetized', 'Diametrically magnetized' or 'Radially magnetized (N on OD)'.
- Pole marks: show N and S on the correct faces or curved surfaces.
If the part is a ring, also state whether the pole is on the outer diameter, inner diameter or across the wall, because 'radial' alone can be read two ways.
Common specification errors
- Marking only 'magnetized' with no direction.
- Assuming axial when the assembly needs a side field.
- Confusing inner-diameter and outer-diameter radial poles.
- Forgetting multi-pole count when a fine pattern is required.
Quick selection guide
Choose axial when
- The magnet holds or couples along its thickness.
- A flat-face sensor or stack reads the field.
Choose radial / diametric when
- A sensor or stator sits at the curved surface.
- Rotation or angle must be detected.
- The field must cross the diameter, not the thickness.
A worked encoder example
Suppose a design needs to read shaft angle with fine resolution. An axially magnetized ring produces a field pointing up and down; a sensor mounted above the ring sees almost no change as the shaft turns, so the signal is flat and useless. Switch to a diametrically or radially magnetized ring and the field now points outward and sweeps past the sensor once (or several times, for a multi-pole ring) per revolution. The sensor sees a clean periodic signal and the angle is recoverable. Same ring material, opposite behaviour, decided entirely by magnetization direction.
This is why the direction is never an afterthought: it is part of the sensing principle.
Fixture and verification notes
Magnetization is set during manufacture in a fixtured field, so the direction and pole count are manufacturing parameters, not something you adjust later. For multi-pole rotors, verify the pole count and sequence on samples before a production run, because a single mis-magnetized ring can make a whole motor or encoder misbehave. Keep the magnetization callout on the drawing unambiguous and reference it in the inspection plan.
Marking poles in production
Because the difference between a usable magnet and a scrap one is often just the magnetization direction, production marking matters. Colour dots, laser marks or stamped N/S on the correct surfaces let assemblers place the part without guesswork and let inspection confirm orientation before the magnet disappears into a sealed unit. A few cents of marking prevents a costly misbuild.
Common misreads
The two mistakes that recur are treating 'magnetized' as a complete instruction and assuming radial always means pole-on-outer-diameter. Neither is safe. Always state the axis or pole location explicitly, and for rings confirm whether the pole sits on the outer diameter, inner diameter or across the wall. The drawing, not the material name, is what the magnetiser builds to.
Frequently asked questions
The direction questions that most often stall a first order.
What is the difference between axial and radial magnetization? Axial puts the poles on the flat faces so the field runs along the axis; radial puts the poles on opposite curved surfaces so the field crosses the diameter.
What is diametric magnetization? It is the two-pole form of radial magnetization, with a single north-south pair across the diameter of a rod or ring.
How do I show magnetization on a drawing? Draw an arrow for the magnetization axis and label the N and S poles, plus a text callout such as 'diametrically magnetized' or 'radially magnetized, N on OD'.
Can the same ring be multi-pole? Yes. Rings can be magnetized with several poles around the circumference for encoders and fine-resolution rotors, but the pole count must be specified at magnetization.
Which direction does a rotary sensor need? Usually radial or diametric, so the field sweeps past the sensor as the shaft turns; axial magnetization would give little variation with rotation.
Unsure which magnetization direction your assembly needs? Request a quote and our team will help you specify axial, diametric or radial orientation correctly.