Choosing a magnet grade for a motor is three decisions in one: the energy grade, the temperature suffix and the geometry. They interact, and the order matters.
Decide the temperature suffix first
The suffix — none, M, H, SH, UH or EH — sets the operating temperature: 80, 100, 120, 150, 180 or 200℃ respectively. It is decided by the hot spot, not the average, because a magnet that reaches its limit early in a hot soak loses flux irreversibly.
Get this wrong and no amount of energy grade rescues the design. Get it right and the energy grade becomes a straightforward economic choice.
Then the energy grade
Within the chosen suffix, the energy grade — N35 through N58 — decides how much flux the part delivers. Start at N42 and climb only as far as the force target requires. In most motor designs N42 to N48 is the economic band; N52 is for the cases where the envelope is genuinely fixed.
Remember that a grade step changes the material cost and the process yield, while a geometry change changes the envelope. Which one is cheaper depends on how tight the design is.
Then the geometry
Arc and segment shapes are the motor default, supplied as matched sets so the pole pattern closes. Segment count, skew and retention all affect the result, and they are specified with the drawing rather than chosen from a catalogue.
For hot motors, the segment geometry also affects demagnetisation margin: a thicker segment in the magnetization direction resists demagnetisation better than a thin one at the same grade.
The common mistakes
- Sizing at room temperature and hoping the flux holds in service.
- Specifying SH for a cool motor — paying a material premium plus a licence for coercivity the circuit cannot use.
- Jumping to N52 when N48 would have closed the gap.
- Forgetting that high-coercivity grades deliver slightly less flux at cold, and sizing the circuit for the wrong number.
What to send with the enquiry
Send the pole geometry, the force or field target, the ambient and hot-spot temperatures, the retention method and the volume. With those five points the grade, suffix and geometry can be proposed together rather than guessed.
Frequently asked questions
Which grade should I start with for a motor? N42, then climb only as far as the force target requires. N42 to N48 is the economic band for most motor designs.
How do I know if I need an SH grade? Check the hot-spot temperature. Above 120℃ look at SH (150℃); between 80 and 120℃ look at H. If the part never exceeds 80℃, standard grades suffice.
Do high-temperature grades cost more? Yes — the heavy rare-earth addition raises material cost, and the Dy-bearing grades also carry export licences and end-use review.
Are motor segments supplied as matched sets? Yes. Segments for one rotor are ground, magnetized and inspected as a set so the pole pattern closes correctly around the ring.
If your application is covered here, Request a quote with the drawing or the duty conditions and we will confirm what is feasible.